Wireless Telemetry Temperature Acquisition Module (T24-TA)
View more videos on
Our YouTube Channel !
- Miniature acquisition module for wireless Pt100 type 385 sensors
- Creates wireless temperature link
- Exceptionally low power for long battery life
- Transmits on license free 2.4GHz
- Remote ‘on’ and ‘off’ to preserve battery life
- Up to 200m range
- Simple configuration and calibration via PC using Free Telemetry Toolkit Software
- Can be calibrated to provide any standard engineering unit output for a given input
- 1 year manufacturers warranty
- Thumbnail photos on left shows the case options available (mini, for integration and standard)
The T24-TA temperature acquisition module is a high performance device designed for OEM integration for the collection and processing of temperature measurements. The wireless module requires an external platinum temperature sensor (Pt100 type 385).
Measuring temperature and periodically transmitting, between transmissions the device can be placed in a power saving sleep mode to conserve batteries. Miniature in size, the wireless temperature PCB transmits on license-free 2.4Ghz, avoiding local radio interference to ensure data integrity and security.
Data is provided in real time at variable speeds with a direct line of sight range of up to 200 meters.
Integral antenna options offers up to 100m (325ft) range (T24-TAi) and external antenna options offering up to 200m (650ft) range in an open field.
Click to view a selection of suitable antennas. This device is also available in a selection of IP rated enclosures to provide housing and powering. See T24-ACM-TA, T24-ACMi-TA and T24-ACMm-TA
General Radio |
|||||
|---|---|---|---|---|---|
| Parameter | Min | Typical | Max | Units | |
| Licence | Licence Exempt | ||||
| Modulation Method | MS(QPSK) | ||||
| Radio Type | Transceiver (2 way) | ||||
| Data Rate | 250 | K bits/sec | |||
| Radio Frequency | 2.4000 | 2.4835 | GHz | ||
| Power | 1 | mw | |||
| Range RAD24i (Integrated antenna) | 100 (400) | Metres (feet) * | |||
| Range RAD24e (External antenna) | 200 (650) | Metres (feet) * | |||
| Channels (DSSS) | 16 | ||||
| *Maximum range achieved in open field site with the T24 acquisition module at a height of 3 metres (9.8 feet) above ground and T24-HS held at chest height pointing towards the acquisition module. Specification at 3V supply at 25°C | |||||
T24-TA |
|||||
| Measurement | Min | Typical | Max | Units | |
| Temperature Range | -200 | 500 | °C | ||
| Accuracy (-20 to +40 °C) | 0.1 | 0.2 | °C | ||
| Accuracy (-40 to +80 °C) | 0.2 | 0.35 | °C | ||
| Internal Resolution | 16,000,000/24 | Resolution/Bits | |||
| Noise Free where Sample TIme < 5mS | 13,000/13.5 | Resolution/Bits | |||
| Noise Free where Sample TIme < 10mS | 17,000/14 | Resolution/Bits | |||
| Noise Free where Sample TIme < 100mS | 62,000/16 | Resolution/Bits | |||
| Noise Free where Sample TIme < 1000mS | 158,000/17 | Resolution/Bits | |||
| Electrical | Min | Typical | Max | Units | |
| Power Supply Voltage | 2.1 | 3.0 | 3.6 | VDC | |
| Power Supply Ripple | 50 | mV ac pk-pk | |||
| Power | Min | Typical | Max | Units | |
| Normal Mode (Non Low Power Mode) | 55 | 65 | mA | ||
| Standby / Low Power Mode | 5 | 20 | uA | ||
| Environmental | Min | Typical | Max | Units | |
| Operating Temperature Range | -40 | +85 | °C | ||
| Storage Temperature | -40 | +85 | °C | ||
| Humidity | 0 | 95 | %RH | ||
| Physical | |||||
| PCB Dimensions | 16.8 x 37.5 x 6.5mm | ||||
Module transmits and receives giving:
1. Full error detection and correction
2. Ability to switch to low power modes
3. Calibration & configuration via radio telemetry
4. Ability to be switched from sleep to operating mode via radio
5. Calibration stored within the module
6. Remote battery check

Software
No relevant software available
Product order options
| T24-TA | Code |
|---|---|
| Temperature Acquisition with fitting for External Antenna | T24-TAe |
| Temperature Acquisition with Internal Antenna | T24-TAi |
These are the following industries and applications in which this product has been used:
- Automotive - Measuring the Output Power of a Motor
- Agriculture - Vessel Level Control & Flow Sensing
Wireless Sensing Module for Load Cell, Strain Gauge Data Acquisition
Wireless Sensor Converter for Strain Gauge Sensors, 0-20mA, 0-10V
Radio Telemetry Module for Strain Gauge, 0-20mA, 0-10V Sensors
Handheld Telemetry Display with Multiple Inputs
Wireless Telemetry Handheld Display Single Input
Wireless Strain Indicator Unlimited Inputs
- Q: What type of sensor can I use with this device?
A: The T24-TA module is factory calibrated to work with PT100 (Type 385) sensors which have a defined change in resistance per degree. (DIN 43760)
- Q: What wiring configurations are available?
A: The T24-TA can be wired in 2, 3 and 4 wire configurations; users are able to choose the best option for their application depending on accuracy requirements, cost and distance between acquisition module and probe.
- Q: What units are available?
A: The T24-TA can output values in degrees Celsius, degrees Fahrenheit, Kelvin or Ohms.
- Q: Is there a way to apply a custom calibration?
A: There is no custom calibration on this device however an offset can be applied to any outputted values.
- Q: How can I account for long cable length when performing two wire measurements?
A: There is a custom offset that can be used. This can be used to offset a temperature inaccuracy due to long cable lengths when using two or three wire connections.
- Q: What software is provided with the T24 devices?
A: All devices are supported by the T24 Tool Kit which allows users to
configure all devices from the T24 range as well as view and log data from
acquisition modules in range. The software can also be downloaded directly
from our website.
- Q: How many devices can operate on one radio channel?
A: Many devices can operate on the same radio channel depending on the sample rate of the acquisition modules present in the system. There are 16 channels available with each one capable of supporting up to 200 data packets per second.
- Q: Can PC software gather data from many devices?
A: Yes, Mantracourt provides freeware for logging up to 24 inputs to one base station, in addition the open COM driver can be used to gather data through customers own PC software to applications in Visual Basic which in turn has been used to integrate the T24 system with Lab View.
- Q: What limits the RF range of the devices?
A: Any metal surface will reflect 2.4 GHz radio waves, therefore in a sealed metal box, no RF will escape. However by providing a suitable RF window the signals will propagate out.
- Q: What Frequency does the system operate on?
A: Licence free world wide 2.4GHz, although this frequency is used by other equipment the T24 range has been tested with Bluetooth, Zigbee & WiFi devices with out conflicts.
- Q: Is the system point to point?
A: Yes, however the modules may also operate in many to one (such as multiple data acquisition modules communicating with a base station) and one to many (such as a data acquisition module supplying data to multiple handhelds and displays).
- Q: Is it possible to use repeaters within T24 network?
A: The T24-AR Active repeater which can be added to the system can propagate a signal around corners and obstacles. This unit can also double the effective range.
- Q: What sensors would these inputs cover?
A: Any sensor that provides a voltage, current or ratio metric interface can be connected to an acquisition module, including load cells, inclinometers, accelerometers, displacement LVDT, pressure, potentiometer, pulse, temperature, humidity, ph, shock.
- Q: What is the communication protocol?
A: Proprietary protocol based on a 804.15.4 chip. This allows the T24 range to co-exist with Bluetooth, Zigbee & WiFi devices with out conflicts.
- Q: What are the sampling rates of the acquisition modules?
A: The T24 standard acquisition modules (SA, IA, VA, RA, TA, PA) sample from 0-200 updates/sec. The T24-SA fast acquisition modules are fixed at 2,000 updates/sec.
- Q: What is the resolution of the acquisition modules?
A: The noise free resolution for a sample time of 10 milli-seconds or less is 15.5 bits for the T24 SA, 12.5 bits for the T24-VA, 14 bits for the VA and 12.25 bits for the T24IA.
The T24-PA’s accuracy % input error @ 1 Hz is 0.15% and for the T24 RA the accuracy is 0.01% of the full scale.
With increased sample times resolution can be increased up to 18.75 bits for the T24-SA.
- Q: What is the supply voltage for the acquisition modules?
A: 3V for the acquisition modules and handheld displays. Other modules in the range take 9-36 V.
- Q: How are the modules powered?
A: Two standard AA batteries or the T24-BC1 Battery Charger, which provides a re-chargeable power supply using a Li-ion Cell. Find out the battery life of your system using our Battery Calculator.
- Q: Can power be provided to a sensor?
A: Yes, all acquisition modules feature a 5V supply which is the excitation voltage used by the T24-SA strain gauge acquisition module.
- Q: How is the strain gauge acquisition module calibrated?
A: The modules are factory calibrated to 2.5 mV/V which can be custom calibrated and linearised over up to 9 points by using the T24 Toolkit. The T24-SAf has fixed factory calibration and cannot be linearised.
- Q: What is the difference between the ‘i’ and ‘e’ versions of the
A: The ‘i’ modules (T24-SAi, T24-SAfi, T24-VAi, T24-IAi) all feature an on chip
integrated antenna. The ‘e’ modules (T24-SAe, T24-SAfe, T24-VAe, T24-IAe) are
fitted with a miniature UFL connector which can be used with any of the antenna options available; the T24-ANTA (PCB antenna) or T24-ANTB (fixed 90 degree Whip antenna) or T24-ANTC (flexible whip antenna).- Q: How many acquisition modules can be acquired by the base stations?
A: Each base station can use one of 16 channels. From one of those channels a base station can collect data simultaneously from any number acquisition modules depending upon the frequency of readings being provided by the acquisition module.
- Q: What are the input ranges of the T24 acquisition modules?
A: T24-SA 2.5mV/V calibrated strain gauge based measurement; T24-VA 0-10V, T24-IA 4-20mA, T24-TA pt100 sensor input, T24-RA potentiometer 500 to 100000 Ohms and T24-PA 0.5Hz to 3kHz.