Load Cell Amplifier and Digitiser PCB (LCB)

Load Cell Amplifier and Digitiser PCB
Ask an engineer Forward to a colleague
In Stock
Volume Prices Available
How To Buy
Load Cell Amplifier and Digitiser PCB Load Cell Amplifier and Digitiser PCB
  • Simple one pass auto calibration
  • Excitation 10V 160mA for up to 6 Load Cells
  • Sensitivity from 0.5 to 200 mV/V
  • 6 wire input to compensate for barrier and cable losses
  • Full digital set-up and calibration using keypad or PC
  • Auto tare and peak hold actioned by volt-free contacts
  • Fully isolated 4-20mA and 0-10V analog outputs
  • 2 Setpoints SPCO relay outputs
  • RS485 RS232 Digital data output for communications and printing
  • PCB (LCB shown in main photo) options include various cases with or without DIN rail mounting (shown in photos on left)

The LCB Weighing Amplifier / Digitizer OEM PCB is a very flexible digital signal conditioning amplifier for single or multiple load cell applications, offering very easy one-pass calibration and fast setup.
This versatile load cell indicator offers options of local or remote LCD displays, isolated analogue outputs, latching relays or digital outputs for control or weight alarm functions and in-flight compensation for filling applications.
The RS232 or RS485 options provide for digital communications (including setup) and can support label or ticket printers.

For a bulkhead cased version see model LCA15 Load Cell Amplifier and Digitiser Module
For a rack mounted version, see model RCA Rack Mounted Amplifier / Digitiser.
For wireless radio telemetry version, see model T24 ACM Radio Telemetry Strain Gauge or Load Cell Digitiser.

Inputs
The input is of the Load Cell/Strain Gauge type. With transducer excitation voltage of 9.6 volts @ 160mA to drive 6 x 350R bridges
Compensation by ± sense wires for cable and safety barrier losses down to 3V excitation
Load cell sensitivity is preset via DIL switches to 0.5, 0.8, 1.0 1.25, 1.5, 2.0, 2.5, 3.5, 5, 10, 20, 50, 100 or 200mV/V
Initial offset is no greater than ± 0.15mV (15uV/V) which is cancelled during auto calibration
Speed is 10 readings per second with a digital filter to reduce speed
Accuracy is 90 days ± 0.08% of reading, +/- 0.05% FSD being typical
Drift is 0.002% per degree C @ 2.5mV/V typical
Resolution 15 bit/ 4.5 digits
Contact Inputs are available for auto tare, print and peak hold reset and are volt free
Analogue Outputs
Drive 4-20mA up to 1Kohm and 0-10 volts up to 2mA
Accuracy 4-20mA + 0.15% of range, typical. 0-10V ±2% before calibration
Resolution as for display up to 13 bits/4.5 digits. Settling time 350mS to within 1% of step change
Isolation ±130V RMS or DC max to analogue input or any other port
Power Supplies
LS1 110V-120V AC or 220/230V AC 50-60Hz 10W
LS3 9-32V DC 10W isolated
Data Retention/Protection
Retention 10 years for set up values, minimum of 100,000 write cycles
Protection of data and function(s) Watchdog timer giving repeat auto resets. Impending power detection and hold off. Keypad security and time out
Other Options & Accessories
2 Set Points Output through 5A 240V AC SPCO Relays, with a latching option
Communications Port For data transfer or print via :-
RS485 Enabling up to 25 units to be multi dropped
RS232 For 1 to 1 connection and standard printer drive
Printer Operation By closure of volt free contact
Baud Rates 300, 600, 1200, 2400, 4800, 9600 (19200 MANTRABUS only)
Die Cast Case Sealed to IP65 with external dimensions of 220 x 120 x 80mm max
Stainless Steel Case Sealed to IP65, with external dimensions of 224 x 160 x 90mm
Environmental
Storage Temperature -20 to +70ºC
Operating Temperature -10 to 50ºC
Relative Humidity 95% maximum non condensing
CE Environmental Approvals European EMC Directive 2004/108/EC, Low Voltage Directive 2006/95/EC

 

  • product logo
  • product logo
  • product logo

Weight indicator with simple one pass auto calibration has full digital set-up and calibration using keypad or PC

Software

No relevant software available

Product order options

Please read the following before selecting the options for this product:

LCB15 Standard Instrument with 4-20mA/0-10V Analogue Outputs. Signed 15 Bit 100mS update, without case.

Starting with the base model LCB select the options that you need to configure the device to meet your needs.

Base UnitCode
Load Cell Input Amplifer PCB Only LCB
InputsCode
Fast Load Cell Input for Universal Amplifier Board UAFLC
OutputsCode
Universal Amplifier Fast Analogue Output UAFAO
CommsCode
20mA Current Loop for MODBUS RTU, ASCII & MANTRABUS LC1
RS485 Comms LC3
Relay OutputCode
Relay Output 2 x SPCO 5A LR1
Power SuppliesCode
LCA15 AC Power Supply LS1
9-30V DC Power Supply LS3
DisplayCode
On Board Display Programmer LP1
Remote Hand Held Programmer LP2
Mounting EnclosureCode
ABS Case with plain ABS Lid LAB
ABS IP65 Case and Mountings LAC
Die Cast Case with PG9 Glands 220 x 120 x 80mm LDC
Stainless Steel Case 224 x 160 x 90mm LSS
DIN Rail Mounting Fixture D2
Case and DIN Rail Mounting for DSJ4, LCA, UAB, JBA D3
Extended MountingCode
Transparent Plastic Case Lid for ABS Case (available with LAB) LTL
Panel Mount Weighing Indicator and Controller

Panel Mount Weighing Indicator and Controller

ADW15
Enclosure for 1 x DSC (Strain Gauge or Load Cell Digitiser Module)

Enclosure for 1 x DSC (Strain Gauge or Load Cell Digitiser Module)

DSJ1
Rack Mount Load Cell Amplifier and Digitiser

Rack Mount Load Cell Amplifier and Digitiser

RCA15
Contact Us

t: +44(0) 1395 232020
e: info@mantracourt.co.uk

e-newsletter sign up