Versatile Indicator/Controller with up to 16 Set Points (ADP-SP16)
- Up to 16 set point relays (Rating 230V @ 5A AC)
- All settings programmable from ADP15 keypad
- Individual programmable setpoints & hysteresis values
- Wide choice of input modules with transducer excitation
- Industry Standard Analogue Outputs
- Data Communications, Printer Driver
- VisualLink SCADA software (optional)
- AC or DC power supply options
The ADP-SP16 Versatile Indicator / Controller has up to 16 relay Set Points and a wide range of input options including, volts, amps, temperature, frequency, speed, load, force, pressure, torque, LVDT and many more.
The digital architecture offers very easy one-pass calibration and fast setup. This versatile amplifier panel meter offers options of isolated analogue outputs, latching relays or digital outputs for control or alarm functions.
The RS232 or RS485 options provide for digital communications (including setup) and can support label or ticket printers
| Inputs | |
|---|---|
| Temperature - PT | Resist Bulb PT100 |
| T1 | Thermocouple Type K |
| T2 | Thermocouple Type J |
| T3 | Thermocouple Type R |
| T4 | Thermocouple Type S |
| T5 | Thermocouple Type T |
| T6 | Thermocouple Type B |
| T7 | Thermocouple Type N |
| T8 | Thermocouple Type E |
| DC Voltage | ±20mV, ±200mV, ±2V, ±20V, ±200V |
| DC Current | ±2mA, 4 to 20mA (+3.5 to 20.5mA) with 24 V excitation, ±20mA, ±0200mA |
| AC Voltage | 0-200mV, 0-2V, 0-20V, 0-200V |
| AC Current | 0-1A |
| Potentiometer | Any value in the range 100R to 10K V AC |
| Rate & Totaliser Inputs | MV, 5V logic & NAMUR |
| Pressure | Excitation 40mA @ 10V |
| Accuracy | 90 days ± 0.08% of reading ±0.05% of FSD typical |
| DC Analogue Outputs | |
| DC Voltage | 0 to 1V, 0 to 5V, 1 to 5V, 0 to 10V, -10 to +10V, Max Current out 50mA |
| DC Current | 0 to 1mA, 0 to 20mA, 4 to 20mA, 10 to 50mA,0 to 5mA, Max Voltage out 20V |
| Accuracy | Typical ± 0.08% of output, ± 0.08%FSD |
| Resolution | As display resolution, max 15 bits |
| Calibration | By 15-turn pre sets for gain and offset |
| Inversion | By keypad value |
| Isolation | ±130V RMS or DC max to analogue input or to any other port |
| Ranging | Fully keypad scalable over desired display range |
| Communication Port CP Operation | |
| All ADP15 display data can be accessed via the communications port along with relay, PID power and EEPROM status. All ADP15 user configurable data can be changed including EEPROM enable/disable and relay reset. |
|
| Type | Details |
| RS232 | For printer or direct connection to 1 device, 3 wire |
| RS485/422 | For up to 32 instruments on 1 bus, 4 wire |
| Baud Rates | 300, 600, 1200, 2400, 4800, 9600 (19200 MANTRABUS only) |
| Electrical Isolation | ±130V RMS or DC max to analogue input or any other port |
| Formats | MODBUS RTU, MANTRABUS and printer output formats |
| The Relay Output Module | |
| The module consists of 8 relays rated at 230 volts 5 Amps - SPCO, Alarm via 30V 50mA NC contact, DIN rail mounted for a G or top hat profile. Each relay is plug-able and connections are made by 2.5mm field screw terminals. Indication of relay status is shown by LED's. Trip points volt free contact. The module can be situated up to 2 metres from the ADW15 load cell indicator controller. |
|
| Alarm/Control Outputs | |
| SPCO | Up to 16 relays, in multiples of 4, REM4 & REM 8 |
| Relays | 230V at 5A AC resistive |
| Isolation | ±130V RMS |
| Keypad Programmable Options | Hysteresis, Latching, Output Inversion |
| Power Supplies | |
| 220V-230V AC 50-60Hz 10W, 110V-120V AC 50-60Hz 10W, 9-32V DC 10W isolated | |
| Controls | |
| 4 membrane panel keys with tactile feedback. 1 scroll key to view/update parameter. 1 digit select key. 1 digit increment key. 1 reset key. Keypad disable by internal links behind front panel. Hold function by digit select key when in input mode. | |
| Data Retention/Protection | |
| Retention: | 10 years for set up values, minimum of 100,000 write cycles. |
|
Protection of Data and Function(s) |
Watchdog timer giving repeat auto resets. Impending power detection and hold off. Keypad security and time out. |
| Physical | |
| Case Dimensions | DIN 72 x 72 x 163mm (excluding mounting terminal) |
| Case Material | Grey Noryl, flame retardant |
| Weight | 750 grams |
| Terminals | 2.5mm, saddle field terminals |
| Accessibility |
All electronics removable through front panel leaving field wiring and case in situ. |
| Environmental | |
| Storage Temperature | -20 to +70ºC |
| Operating Temperature | -10 to 50ºC |
| Relative Humidity | 95% maximum non condensing |
| CE Environmental Approvals | European EMC Directive 2004/108/EC, Low Voltage Directive 2006/95/EC |
.jpg)
Software
Product order options
Please read the following before selecting the options for this product:
ADP15 fitted with special edition 16 Set Point Software with remote driver module to operate the optional 4, 8, 12 or 16 relay remote Din Rail mounted modules, as required. The required number of relay modules must be ordered from the Accessories Section.
Starting with the base model ADP-SP16, select the options that you need to configure the device to meet your needs.
| Inputs | Code |
|---|---|
| Resist Bulb PT-100 | PT |
| Thermocouple Type K | T1 |
| Thermocouple Type J | T2 |
| Thermocouple Type R | T3 |
| Thermocouple Type S | T4 |
| Thermocouple Type T | T5 |
| Thermocouple Type B | T6 |
| Thermocouple Type N | T7 |
| Thermocouple Type E | T8 |
| DC Volt input ±20mV | DCV1 |
| DC Volt input ±20V | DCV2 |
| DC Volt input ±2V | DCV3 |
| DC current input ±20V | DCV4 |
| DC Volt input ±200V | DCV5 |
| DC Current input ±2mA | DCA1 |
| DC Current I/P 4-20mA 24V Exc | DCA2 E |
| DC Current input ±20mA | DCA3 |
| DC current input ±20V | DCV4 |
| ADP15 AC Volt input 0-200mV | ACV1 |
| DC Volt input ±20V | DCV2 |
| AC Current input 0-1A | ACA |
| Rate Totaliser PCB | RTL |
| Potentiometer | RL |
| Outputs | Code |
| ADP15 Analogue Output 0-1V | V1 |
| ADP15 Analogue Output 0-5V | V2 |
| ADP15 Analogue Output 1-5V | V3 |
| ADP15 Analogue Output 0-10V | V4 |
| ADP15 Analogue Output 0-100mV | V5 |
| ADP15 Analogue Output | V6 |
| ADP15 Analogue output 0-1mA | A1 |
| ADP15 Analogue output 0-20mA | A2 |
| ADP15 Analogue output 4-20mA | A3 |
| ADP15 Analogue output 10-50mA | A4 |
| ADP15 Analogue output 0-5mA | A5 |
| ADP15 Analogue output 0-10mA | A6 |
| Comms | Code |
| RS485/232 Comms Module | COM 1 |
| ADP15 Serial Port Fast Format CS1TAR | S1 |
| Power Supplies | Code |
| ADP15 Supply 240V AC | 240 |
| ADP15 Supply 110V AC | 110 |
| 12/24V DC PSU | 12/24 |
| Mounting | Code |
| Panel Mount | P |
| Din Rail Mounting | D |
| Accessories | Code |
| Din Rail Mounted 8 Relay Module | REM8 |
| Din Rail Mounted 4 Relay Module | REM4 |
| Remote PSU (Required for 4+ Relays) | REM PSU |
| REM Interconnection Lead | REMC2 |
| VisualLink SCADA Software Full Version (Ex Works) | VLA |
| VisualLink Runtime Key (Ex Works) | VLR |
| VisualLink Runtime Key USB (Ex Works) | VLRU |
| VisualLink Runtime Software Key (Ex Works) | VLS |
| VisualLink SCADA Software Demo | VLD |